Home / Guides / Draught-proofing

Draught-proofing without blocking ventilation: a spotter's guide

Draughts are uncontrolled air, and vents are controlled air. Six cards show which to seal, which to leave, and how to tell you have gone too far.

Published 2026-11-13. Reviewed 2026-11-13.

The short answer

Seal accidental gaps around doors, windows and floors, and leave the planned openings alone. Energy Saving Trust says good ventilation is still essential, so do not block extractor fans, airbricks, wall vents or trickle vents [1]. If a home has no trickle vents, wall vents or mechanical ventilation, it may already be too airtight for more draught-proofing [1].

Card 1

Light under the door, whistling windows, curtains that move

See
Visible light under or around a door, rattles on windy days, or curtains that stir with the window shut.
Cause
Energy Saving Trust says draughts are uncontrolled air that comes through accidental gaps, and that draught proofing is blocking those unwanted gaps [1].
Test
Energy Saving Trust suggests feeling for moving air around doors, windows, floorboards, skirting boards, pipes through external walls, stairways and fireplaces [1].
Fix
Fit strips to windows and doors that open, a brush or flap to a letterbox and a cover to a keyhole [1]. Leave the gaps that are ventilation, as the next cards show.
Card 2

Trickle vents and wall vents you are tempted to tape over

See
Small slots above the window frame or a vent in a wall, closed or covered because the room feels cold.
Cause
Energy Saving Trust says trickle vents should normally be left open all the time, even in winter, to give a constant and controlled supply of fresh air [2]. CSE also says to keep trickle vents open and to make sure vents and airbricks are not blocked or covered [3].
Test
Open each window frame and check the vent slides open. Look outside for airbricks covered by soil, planting or stored items.
Fix
Reopen them, and clear any blocked airbrick. Energy Saving Trust notes underfloor grilles and airbricks help keep wooden joists, beams and floors dry [1]. See ventilation habits that trap moisture.
Card 3

A foam strip along the bottom of an internal door

See
A bedroom or landing door that closes tight to the carpet, and a stuffy room with misted windows in the morning.
Cause
Energy Saving Trust says internal doors should not be draught proofed, because the gap beneath makes sure air flows through the home [1]. CSE suggests a gap of around 1cm below internal doors [3].
Test
Slide a coin or your fingers under each internal door. If nothing goes under, air cannot move.
Fix
Remove any strip from internal doors. Keep the kitchen and bathroom doors shut while you cook and wash, as CSE advises, to stop steam travelling [3].
Card 4

An unused fireplace that you want to stop the draught

See
Cold air falling into the room from a disused chimney, or a musty smell in the chimney breast.
Cause
Energy Saving Trust says a cap over the chimney pot or a chimney draught excluder reduces draughts, but that excluders should not fully block the chimney so enough ventilation remains, and must be removed if you light a fire [1]. It also says rooms with open fires or open flues must be adequately ventilated [1].
Test
Hold a hand near the fireplace on a windy day. Check whether anything is stuffed up the chimney.
Fix
Use a removable excluder or a ventilated cap, not a solid plug. See chimney breast damp stains.
Card 5

Kitchen, bathroom and gas appliances after you have sealed up

See
Steamed windows after showers or cooking, a stale smell, or a gas hob or flueless heater in a sealed room.
Cause
Energy Saving Trust says you cannot draught proof an extractor fan, that kitchens, bathrooms and utility rooms need ventilation, and that flueless gas appliances need some ventilation to operate safely [1]. It says you must not block fixed ventilation openings needed for flueless or open-flue gas heaters [1].
Test
Switch on the extractor fans and check they run. If you have a gas appliance, check the manufacturer's ventilation instructions.
Fix
Run extractors whenever you shower, bathe or cook, as Energy Saving Trust advises [2]. See kitchen and bathroom extraction.
Card 6

Condensation or mould that showed up after the work

See
Regular streaming windows, new black speckles, or damp, musty smells that take a long time to clear.
Cause
Energy Saving Trust lists ongoing condensation, mould and strong smells that linger among the signs a home needs better ventilation, and says energy upgrades make a home more airtight, so you may need extra ventilation [2].
Test
Keep a log of where and when moisture appears. A hygrometer shows if the air stays damp; see reading a hygrometer.
Fix
Treat mould straight away, as Energy Saving Trust says [2], with a mould and mildew product in preference to bleach, as GOV.UK advises [4]. Then improve ventilation, because removing mould does not fix the cause.

When a dehumidifier is, and is not, the answer

A dehumidifier is not the fix for a leak, a blocked vent or rising damp, and it does not remove mould that is already growing; that has to be cleaned off. Dryzen is not suitable for rented homes unless the landlord authorises the changes, and a home without a loft cannot take the unit. For lofted, owner-occupied homes with condensation-type damp it is one option: 150 m2 coverage and 12 L a day per unit, an activated carbon filter, and about 20 GBP a year to run. It aims for 50 to 55 per cent humidity, inside the supported 40 to 60 per cent band.

Questions

Can draught-proofing cause damp?

It can if it cuts off the air that carries moisture out. Energy Saving Trust says that if a home is already fairly well draught proofed, adding more may increase the risk of poor air quality, and that vents, extractor fans and airbricks should not be blocked. Seal accidental gaps, not planned ventilation.

Should I draught-proof internal doors?

No. Energy Saving Trust says internal doors should not be draught proofed, so there is a gap beneath them for air flow around the home, and CSE suggests a gap of around 1cm below internal doors.

Will a dehumidifier fix damp caused by over-sealing?

Not on its own. Uncover the vents first. Where condensation-type damp remains, a loft-mounted dehumidifier system can help stop the conditions mould needs in an owner-occupied home with a loft, but it does not clean mould already growing.

Sources

  1. Energy Saving Trust, Draught proofing. what to seal, what not to block
  2. Energy Saving Trust, Ventilation. trickle vents, extractors, signs of poor ventilation
  3. CSE, Damp and condensation. vents, internal door gaps
  4. GOV.UK, Understanding and addressing the health risks of damp and mould in the home. cleaning mould, finding the cause

Sealed up and now damp?

Book a free survey. We come out, have a proper look and tell you honestly what we think it is. Nothing to pay, nothing to sign.

Book a free survey